Determination of Heat Transfer Coefficient in Solar Collector Tube under Simulated Operating Conditions

Autori

  • Vishwash K. Deshpande Retired Professor Nagpur, Maharashtra, India
  • Sampatrao D. Manjare BITS - Pilani, K K Birla, Goa Campus Zuari Nagar 403 726 Goa India Ph. no. 0832-2580112 (O)

Parole chiave:

heat transfer coefficient, scale thickness, Reynold number, thermosiphon, hot water system

Abstract

In this paper, heat transfer coefficient, in solar collector tube under scaling conditions has been experimentally determined using a specifically fabricated test apparatus.  The effect of various variables such as  scale thickness, flow conditions and tube wall temperatures on heat transfer coefficients have been investigated. The experimental results reveals that the scale thickens has a dominating effect on heat transfer coefficient.Keywords:  Heat transfer coefficient, scale thickness, Reynold number, thermosiphon, hot water system

Biografia autore

  • Sampatrao D. Manjare, BITS - Pilani, K K Birla, Goa Campus Zuari Nagar 403 726 Goa India Ph. no. 0832-2580112 (O)
    Department of Chemical EngineeringInstitute rank is 6th

Pubblicato

2013-03-21

Fascicolo

Sezione

Research Articles