Flush Air Data System(FADS) Validation in a Subsonic Wind Tunnel
Résumé
Flush air data sensing system (FADS) makes use of surface pressure measurements from the nose cap of the vehicle for deriving the air data parameters of the vehicle such as angle of attack, angle of sideslip, Mach number, etc. The overall FADS system including pressure transducers, tubing, port geometry, FADS algorithm, and electronics along with the mechanical and electrical integration scheme is successfully tested in a subsonic wind tunnel facility. The tests are carried out in a low speed wind tunnel at wind speed of 65 m/s (Mach=0.2). For each blow-down, angle of sideslip (beta) is set at one value and angle of attack (alpha) is varied. Air data measurements (alpha, beta, Mach number) in each blow-down is analyzed and compared with the set conditions. For first developmental flights, the demanded accuracies from FADS are of the order of +/–2° in alpha and beta. Details of the FADS system, the embedded algorithm and the various interfaces are explained. The tests conducted and the performance obtained by comparing with the set conditions is presented in this paper. The experimental result establishes that the accuracies demanded are provided by the system. Keywords: FADS, subsonic, angle of attack, wind tunnelCite this Article Vidya SB, Jayakumar M, Finitha KC et al. Flush Air Data System (FADS) Validation in a Subsonic Wind Tunnel. Journal of Aerospace Engineering and Technology. 2016; 6(3): 5–15p.Téléchargements
Publié
Numéro
Rubrique
Licence
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
· I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
· I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
· I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
· I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
_______________
We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |