Performance Comparison of IRT Method with NNMPC Method

Authors

  • S. A. Misal Department of Chemical Engineering, Pravara Rural Engineering College, Loni, Maharashtra, India

Keywords:

IRT, NNMPC, CSTR, Simulink, control, IAE

Abstract

The continuous stirred tank reactor (CSTR) system was used for experimentation and theimproved relay tuning (IRT) method was applied for design of optimum PID settings. The closed loop response was obtained using these optimum PID settings and compared with that of neural network model predictive control (NNMPC) method. The integral absolute error (IAE) criterion for the performance evaluation was used and it was found that the integral error has been decreased by IRT method as compared to that of NNMPC control method. Hence, the IRT method gives improved performance for CSTR system.Cite this ArticleMisal SA. Performance Comparison ofIRT Method with NNMPC Method.Journal of Control & Instrumentation. 2016; 7(2): 1–4p.

Author Biography

  • S. A. Misal, Department of Chemical Engineering, Pravara Rural Engineering College, Loni, Maharashtra, India
    Associate Professor,Department of Chemical Engineering,Pravara Rural Engineering College, Loni-413736, Dist-Ahmednagar, Maharashtra, India.

Published

2016-07-04

Issue

Section

Research Articles