Performance Assessment of IRT Method for Distillation Model Control

Autoři

  • S. A. Misal Department of Chemical Engineering, Pravara Rural Engineering College, Loni, M.S. India
  • V. S. Sathe Chemical Engineering, Dr. Babasaheb Ambedkar Tech. University, Lonere, (M.S). India

Klíčová slova:

IRT, distillation, simulink, control ISE

Abstrakt

A Wood and Berry distillation column was considered for experimentation and the Improved Relay Tuning (IRT) method was applied for design of optimum PID settings. The closed loop response was obtained using optimum values of PID parameters and compared with that ofconventional relay method and other non relay method. The integral square error (ISE) criterion for the performance assessment was used and it was found that the integral error has been decreased by IRT method as compared to other methods. Hence the improved relaytuning method gives better performance for distillation column model.Keywords: IRT, distillation, simulink, control ISE Cite this Article Misal SA, Sathe VS. Performance Assessment of IRT Method for Distillation Model Control. Journal of Control & Instrumentation. 2015; 6(1): 27–30p.

Biografie autora

  • S. A. Misal, Department of Chemical Engineering, Pravara Rural Engineering College, Loni, M.S. India
    Associate Professor,Department of Chemical Engineering,Pravara Rural Engineering College, Loni-413736, Dist-Ahmednagar, Maharashtra, India.

Publikováno

2015-04-06

Číslo

Sekce

Research Articles