Performance Comparison of IRT Method with NNMPC Method

Авторы

  • S. A. Misal Department of Chemical Engineering, Pravara Rural Engineering College, Loni, Maharashtra, India

Ключевые слова:

IRT, NNMPC, CSTR, Simulink, control, IAE

Аннотация

The continuous stirred tank reactor (CSTR) system was used for experimentation and theimproved relay tuning (IRT) method was applied for design of optimum PID settings. The closed loop response was obtained using these optimum PID settings and compared with that of neural network model predictive control (NNMPC) method. The integral absolute error (IAE) criterion for the performance evaluation was used and it was found that the integral error has been decreased by IRT method as compared to that of NNMPC control method. Hence, the IRT method gives improved performance for CSTR system.Cite this ArticleMisal SA. Performance Comparison ofIRT Method with NNMPC Method.Journal of Control & Instrumentation. 2016; 7(2): 1–4p.

Биография автора

  • S. A. Misal, Department of Chemical Engineering, Pravara Rural Engineering College, Loni, Maharashtra, India
    Associate Professor,Department of Chemical Engineering,Pravara Rural Engineering College, Loni-413736, Dist-Ahmednagar, Maharashtra, India.

Опубликован

2016-07-04

Выпуск

Раздел

Research Articles