Design of EMG based Control System for Prosthetic Arm
Keywords:
ADC, analog to digital converter, EMG, electromyography, CMRR, common mode rejection Ratio, op-amp, operational amplifierAbstract
Prosthesis, field of bio-mechatronics, is an artificial extension used to replace the function or appearance of a missing limb or lost body part due to injury (traumatic), to correct congenital deficiencies or to supplement defective body parts. A myoelectrically controlled prosthesis detects muscle contractions using electrodes and this electrical activity acts as a signal to activate the prosthesis. In the presented work, the EMG signal is acquired using surface electrodes placed on the muscles. The acquired signal is then processed using Signal Conditioning Unit in order to amplify, filter and buffer. The EMG signal is very noisy and the noise components are of high frequency (more than 200 Hz of few mv). A low pass, 2nd order Butterworth filter of 100 Hz is used to extract the EMG signal from the human muscle. The filtered output is buffered using the unit gain operational amplifier configuration. The final output signal is converted to a digital signal using 16-bit serial ADC. Once the EMG signal is available in digital form, the same can be utilized to control the robotic arm or in any application. Keywords: ADC: analog to digital converter, EMG: electromyography, CMRR: common mode rejection Ratio, op-amp: operational amplifierDownloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
· I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
· I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
· I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
· I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. _______________
We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |