Detecting Winding Movement by Fuzzy Logic for Frequency Response of Power Transformer
キーワード:
comparative Standard Deviation (CSD)、 Cross Correlation coefficient(CCF)、 Root Square Error(RSQ)、 Fuzzy controller、 Sweep Frequency Response Analysis(SFRA)要旨
Power transformers are basically one of the most efficient devices that are used in Power Plant or in any substation. Its maintenance is bit some tedious but has to be done to diagnose any severe fault that may damage the transformer. Sweep Frequency Response Analysis (SFRA) is used to detect any winding or core deformation in transformer that would arise during transportation, due to severe short circuits or due to ageing. In this paper interpretation of the signatures of SFRA is done for different case studies using different statistical tools like Cross correlation coefficient(CCF) Root Square Error(RSQ),Comparative Standard Deviation(CSD) and then based on these parameters a fuzzy model have been developed for diagnosis of fault and limit is created for different fuzzy output in different sub-frequency range. Then based on the output variation of different statistical parameters and fuzzy output vs. frequency is drawn for determining the state of transformer. Keywords: Comparative Standard Deviation (CSD), Cross Correlation coefficient (CCF), Root Square Error (RSQ), Fuzzy controller, Sweep Frequency Response Analysis (SFRA) Cite this ArticleSrivastava R, Singh SK, Sood YR. Detecting Winding Movement by Fuzzy Logic for Frequency Response of Power Transformer. Journal of Power Electronics and Power Systems. 2015; 5(3): 25–34p.発行日
巻号
セクション
ライセンス
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
· I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
· I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
· I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
· I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. _______________
We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |