Shunt Active Power Filter Using Three Level Inverter without PI Controller
キーワード:
Shunt active power filter、 NPC (Neutral Point Clamped) inverter、 FFT (Fast Fourier Transform)、 space vector hysteresis current control、 DC link voltage control.要旨
This paper presents simulation and analysis of shunt active power filter using three level inverter. Different types of filters can be used for elimination of harmonics in the power system with nonlinear load. Three level VSI (Voltage Source Inverter) can be used for high voltage application. Three level NPC (Neutral Point Clamped) VSI is used for active power filter. In this paper, FFT (Fast Fourier Transform) algorithm for reference current generation is discussed. Also space vector hysteresis current control method is implemented for simulation. DC link voltage control can be achieved through calculating the energy required to stabilize the DC bus. NPC topology has problem of capacitor voltage unbalancing. In this work capacitors voltage are balanced by using redundant space vectors of three level inverter. Control algorithms are verified using Power Simulator Software (PSIM) simulation results with DLL block and C code. In this proposed work, PI controller has not been used for overall control of shunt active power filter. Keywords: Shunt active power filter, NPC (Neutral Point Clamped) inverter, FFT (Fast Fourier Transform), space vector hysteresis current control, DC link voltage control Cite this Article Pinkal J. Patel, Rajesh M. Patel, Vinod Patel. Shunt Active Power Filter Using Three Level Inverter without PI Controller. Journal of Power Electronics and Power Systems. 2015; 5(3): 76–86p.発行日
巻号
セクション
ライセンス
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
· I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
· I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
· I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
· I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. _______________
We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |